Designed for controlled laboratory, engineering and optical evaluation environments, this 130W portable infrared laser system combines high optical output with an integrated rechargeable power supply, adjustable focusing optics and automatic thermal protection.
The compact silver housing measures only 52 × 52 × 170 mm, allowing the laser source, battery system, electronics and optical assembly to be integrated into a self-contained professional platform.
A coaxial red alignment beam and adjustable 15× optical system provide convenient visual positioning and optical configuration for trained professional users.
![]()
The system is built around a 130W infrared laser source intended for professional technical applications.
Because the primary infrared radiation is not directly visible to the human eye, operation requires appropriate wavelength-specific laser safety controls.
A separate low-power red guide beam is integrated into the optical axis to provide a visible reference during controlled alignment.
The front optical assembly incorporates a 15× telescopic focusing lens.
Focusing can be adjusted manually through the sliding and telescopic lens structure, providing greater flexibility than a fixed-focus optical configuration.
The optical components should be kept clean and protected from dust, fingerprints and impact to maintain consistent optical performance.
Portable power is supplied by four Samsung 50S rechargeable lithium-ion cells.
Each cell has a rated capacity of 5000mAh and is designed for high-current applications, making the battery configuration suitable for the power requirements of the integrated laser system.
Under typical operating conditions, available operating time can reach approximately one hour. Actual runtime will vary according to operating cycle, battery condition, ambient temperature and system load.
A 15mW visible red alignment laser is incorporated into the optical system.
Its purpose is to provide a visible positioning reference for the otherwise invisible infrared laser path.
The alignment beam should be treated as an optical positioning aid only and does not indicate that the primary infrared output is safe to view.
A three-color battery indicator provides a convenient reference for checking the system's remaining power status.
This allows operators to verify battery condition before use and reduce the likelihood of unexpected power interruption during controlled technical work.
Charging is handled through a dedicated DC charging interface.
High-output laser systems generate considerable heat, particularly when installed in compact enclosures.
An internal thermal protection system continuously monitors operating temperature. If temperature exceeds the permitted range, laser output can be automatically suspended to reduce thermal stress on the laser source and control electronics.
Operation can resume after the system has cooled to an appropriate operating temperature.
The 130W system is built into a compact cylindrical-style silver enclosure.
With dimensions of approximately 52 × 52 × 170 mm and a net weight of around 1025 g, the design offers a balance between portability, integrated power and mechanical stability.
Its self-contained architecture makes the unit easier to transport and store than conventional laser systems requiring separate bench-mounted power and optical components.
![]()
This system is intended for controlled technical environments including optical evaluation, laboratory research, engineering development, equipment testing, scientific demonstrations and professional system-integration projects.
It is not intended as a recreational laser product or for unrestricted operation in public environments.
OEM and private-label configurations may be available for distributors, laboratories and system integrators depending on technical requirements and order volume.
The standard package includes the 130W infrared laser main unit, adjustable focusing lens and compatible charger.
A protective storage case may also be available as an optional package configuration.
Customers purchasing for laboratory or engineering projects should confirm the current product configuration and package contents before ordering.
This product contains a high-power invisible infrared laser source and must only be operated by trained adults in an appropriate controlled environment.
Direct or reflected laser exposure can cause severe and permanent eye or skin injury and may create a fire hazard.
Appropriate wavelength-specific protective eyewear, controlled access, beam containment and other engineering safeguards should be established before operation.
Never direct laser radiation toward people, animals, aircraft, vehicles, cameras, optical sensors, reflective surfaces or public areas.
The equipment should be stored securely when not in use and kept inaccessible to children and unauthorized personnel.
Users are responsible for confirming and complying with applicable laser-safety, import, transportation and workplace requirements in their jurisdiction.