logo
Send Message
Home > Products >
Medical Safety
>
Lead-Lined Ventilation Louver for X-Ray Room Radiation Shielding

Lead-Lined Ventilation Louver for X-Ray Room Radiation Shielding

Product Details:
Place of Origin: China
Brand Name: Xinland
Detail Information
Place of Origin:
China
Brand Name:
Xinland
Product Name:
Lead-Lined Radiation Shielding Ventilation Louver
Product Type:
X-Ray Protective Air Vent
Shielding Material:
Lead
Standard Lead Equivalence:
0.5mmPb
Dimensions:
Customized
Primary Application:
Medical X-Ray Room Ventilation
Trading Information
Minimum Order Quantity:
1pc
Price:
Negotiated
Payment Terms:
T/T, Western Union, , D/P, D/A, L/C
Supply Ability:
10000pcs per month
Product Description

Product Overview

Our lead-lined ventilation louver is designed for medical imaging facilities where air circulation and radiation shielding must be considered together. It provides a specialized solution for ventilation openings in X-ray rooms, radiology departments, and other healthcare environments with lead-lined walls.

Unlike conventional ventilation grilles, this radiation shielding air vent incorporates lead-based protective elements within a louvered structure. The internal arrangement is designed to reduce direct radiation transmission paths through wall openings while maintaining a passage for ventilation airflow.

The standard product features a nominal lead equivalence of 0.5mmPb, with alternative shielding configurations available for customized projects.

Manufactured according to project requirements, the louver can be adapted to different wall openings, duct connections, shielding specifications, and installation conditions.

It is an ideal component for hospital construction contractors, radiation protection engineering companies, HVAC system integrators, and medical facility renovation projects.

 

Key Product Features

1. Integrated Ventilation and Radiation Shielding

The lead-lined louver combines an airflow passage with shielding elements to help address radiation protection requirements at ventilation openings in medical X-ray rooms.

2. Specialized Lead Louver Construction

The internal lead elements are arranged to reduce unobstructed radiation paths through the ventilation opening. The blade configuration can be designed around the required shielding level and available installation space.

3. Customizable Lead Equivalence

The standard nominal shielding specification is 0.5mmPb. Alternative lead equivalence requirements can be considered for projects with different radiation shielding designs.

4. Adaptable to Hospital HVAC Systems

The ventilation louver can be configured for integration with air supply or return openings, subject to the ventilation system design and required airflow performance.

5. Custom Dimensions and Frame Design

Overall width, height, frame depth, mounting flanges, and connection details can be customized according to architectural drawings and HVAC specifications.

6. Suitable for New Construction and Renovation

The product can be incorporated into new X-ray room installations or existing medical facility upgrades where ventilation openings require radiation shielding consideration.

 

Technical Specifications

Parameter Specification
Product Name Lead-Lined Radiation Shielding Ventilation Louver
Product Type X-Ray Protective Air Vent
Shielding Material Lead
Standard Lead Equivalence 0.5mmPb
Lead Strip Size 25 × 0.16 mm
Structure Radiation Shielding Louver
Installation Wall Ventilation Opening
Airflow Application Supply / Return Air, Subject to Design
Dimensions Customized
Frame Configuration Project-Specific
Lead Equivalence Options Customizable
Primary Application Medical X-Ray Room Ventilation
OEM / ODM Available

Note: The nominal lead equivalence and lead strip dimensions describe the stated product specification. Final shielding performance depends on the complete louver configuration, radiation energy, installation details, and project verification.

 

How Does a Radiation Shielding Louver Work?

A conventional air grille provides an opening for ventilation but does not necessarily address radiation transmission through a shielded wall.

A lead-lined radiation shielding louver uses protective material and a specially arranged internal blade structure to create a less direct pathway through the ventilation opening.

Air can pass through the spaces between the louver elements, while the shielding geometry is intended to reduce direct radiation streaming through the wall penetration.

The complete design must account for both radiation protection and HVAC performance, including airflow capacity, pressure drop, shielding overlap, and surrounding wall construction.

 

Typical Applications

Our lead-lined ventilation louvers are suitable for radiation-controlled facilities requiring specialized air ventilation openings.

Common applications include:

  • Hospital X-ray examination rooms
  • Digital radiography (DR) rooms
  • Radiology departments
  • Fluoroscopy examination rooms
  • Medical imaging facilities
  • Lead-lined diagnostic rooms
  • Healthcare radiation shielding renovation projects
  • Custom medical facility HVAC installations

 

Benefits for Hospital Construction Projects

Maintain Shielding Continuity

The louver can be integrated with the surrounding lead-lined wall to help address potential shielding gaps at ventilation penetrations.

Coordinate With Ventilation Requirements

Customized louver dimensions and internal arrangements allow the ventilation opening to be designed with consideration for the required airflow and acceptable system resistance.

Simplify Project-Specific Sourcing

Contractors can order ventilation shielding components according to approved room layouts and construction drawings instead of relying on standard commercial air grilles.

Support Different Wall Structures

Frame depth, mounting details, and perimeter overlap can be adapted to different wall thicknesses and lead-lining arrangements.

Suitable for Professional Project Procurement

The product is intended for radiation shielding contractors, healthcare construction companies, HVAC engineering firms, and medical equipment installation specialists.

 

Custom Manufacturing & OEM / ODM Services

We provide custom manufacturing solutions for radiation shielding ventilation components.

Available customization options include:

  • Custom overall width and height
  • Different lead equivalence specifications
  • Customized lead blade arrangements
  • Frame depth and mounting flange dimensions
  • Wall opening and duct connection configurations
  • Perimeter shielding overlap details
  • Installation orientation
  • Surface finish options
  • OEM and ODM project production

For accurate project evaluation, customers are encouraged to provide:

  • Required wall opening dimensions
  • Wall thickness and construction details
  • Specified lead equivalence
  • Ventilation duct dimensions
  • Required airflow volume
  • Acceptable pressure drop
  • Installation drawings or shielding plans

 

Wholesale Supply for Radiation Shielding Projects

We supply customized lead-lined ventilation louvers for medical facility construction, X-ray room installations, and radiation protection engineering projects.

Our solutions are suitable for international distributors, hospital contractors, HVAC equipment suppliers, and radiation shielding specialists.

Whether you need a single customized ventilation opening or multiple lead-lined louvers for a hospital project, we welcome your technical inquiries.

 

Contact us today to discuss your X-ray room ventilation requirements and request a quotation for customized radiation shielding lead louvers.